Rating | 80 deg C, 125 Vac, Horizontal flame. |
|
Conductor | solid or stranded round, tinned or bare copper. |
|
Insulation | Labeled or complying with Manufacturer's AWM Procedure. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. Fillers - (Optional) Required if necessary to form a relatively smooth round core for extrusion of outer jacket.A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional. |
|
Covering | Optional. A 6 mil or heavier PVC covering may be extruded over the conductor assembly. |
|
Jacket | PVC, 22 mils min average, 18 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Probe Cable for use with instruments where shield is grounded. |
|