APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20836 Issued:1994-04-28
Revised:2012-07-27
Style 20836 Jacketed Cable.

Rating80 deg C, 125 Vac, Horizontal flame.
Conductorsolid or stranded round, tinned or bare copper.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. Fillers - (Optional) Required if necessary to form a relatively smooth round core for extrusion of outer jacket.A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional. A 6 mil or heavier PVC covering may be extruded over the conductor assembly.
JacketPVC, 22 mils min average, 18 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseProbe Cable for use with instruments where shield is grounded.

UL and the UL Logo are trademarks of UL LLC © 2024