APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20838 Issued:1994-06-03
Revised:2012-05-30
Style 20838 Multiple-Conductor cable using Non-Integral Extruded Jacket.

Rating105 deg C, 300 Vac, Cable Flame.
InsulationLabeled or complying with manufacturer's AWM procedures.
Inner JacketExtruded PVC, 15 mils minimum average, 12 mils minimum at any point.
BraidAll metal, 25% minimum coverage employed between the inner and outer jackets.
Outer JacketExtruded PVC, 25 mils minimum average, 20 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Interconnection of Appliances.