APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20840 Issued:1994-05-09
Revised:2012-04-13
Style 20840 Multiple-conductor cable using non-integral jacket.

Rating60, 75, 90 or 105 deg C, 300 Vac, FT-2 Flame.
Conductor20 AWG - 18 AWG, stranded, consist of 30 AWG or smaller conductor strands.
InsulationExtruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
AssemblyConsists of two to six insulated conductors, untwisted or twisted pairs or groups of twisted insulated conductors twisted together. The insulated conductors or groups of insulated conductors may be laid parallel forming a flat, oval or round cable. The lay of insulated conductors is not specified.
ShieldOptional - May be applied over the individual conductors or groups of insulated conductors.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal or external wiring.

UL and the UL Logo are trademarks of UL LLC © 2024