APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2085 Issued:1959-05-01
Revised:2011-08-04
Style 2085 Parallel cable with extruded integral insulation and jacket.

Rating105 deg C, 300 Vac, FT2 flame, Optional - 60 or 80 deg C Oil.
ConductorTwo No. 18 or 16 AWG consisting of No. 30 AWG or smaller strands.
InsulationIntegral with Jacket. PVC, 60 mils minimum average, 54 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electric refrigerators where exposed to temperatures not exceeding 105 C; or internal wiring of electric refrigerators where exposed to temperatures not exceeding 105 C or where exposed to oil at a temperature not exceeding (60 C or 80 C, whichever is applicable). Polarity identification may be omitted.