APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20860 Issued:1994-07-28
Revised:2009-02-06
Style 20860 Multiple-conductor cable using non-integral jacket

Rating105 deg C, 300 Vac, Horizontal flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringExtruded PVC or extruded XLPVC, 5 mils thickness. A covering is extruded over the conductor assembly.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024