APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20861 Issued:1994-07-27
Revised:2012-04-23
Style 20861 Bonded flat ribbon cable

Rating105 deg C, 60 Vac, Horizontal flame.
Conductor40 AWG - 12 AWG flat or round, 1.0-10.0 mils thick, 10-100 mils wide.
Insulation(1)non extruded PVC, 3.5 mils minimum bonded each side, or (2) 0.8 mil minimum biaxially oriented PETP film bonded each side with 0.5 mil polyester adhesive, or (3) 0.8 mils minimum PETP film or flame retardant polyester film and 0.5 mil minimum PVC on each side of conductors laminated together. 10 mils minimum edge width and 3 mils minimum between conductors.
AssemblyTwo to 150 conductors Straight or irregular parallel in one plane.
ShieldOptional. Metal faced polyester tape. Drain wire optional.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Class 2 circuits in electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024