Rating | 80 deg C, 300 Vac, Cable Flame. |
|
Conductor | Minimun 36 AWG, solid or stranded. |
|
Insulated Conductor | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Two or more individually insulated conductors or groups of insulated conductors cabled together to form around cable. A flat or oval cable may also be constructed with not more than three rows of single conductors or groups of conductors. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid, paper, nylon, oriented polyethylene terephthalate, or thermoplastic-tape wrap. Such as a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors. |
|
Covering | Optional. Extruded PVC, 10 mils minimum average thickness. |
|
Shield | Optional. |
|
Jacket | Extruded TPU. |
| Diameter of core assembly under jacket* | Minimum average thickness | Minimum thickness at any point |
| 1.500 inch or less | 60 mils | 48 mils |
| 1.501-2.500 | 80 mils | 64 mils |
| 2.501-4.000 | 110 mils | 88 mils |
| 4.001 inch or greater | 140 mils | 112 mils |
| *Major diameter if cable is flat or oval. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection of electronic equipment. |
|