APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20871 Issued:1994-09-12
Revised:2012-01-12
Style 20871 Multiple conductor cable using non-integral jacket

Rating60 deg C, 300 Vac, Cable flame.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer (braid) and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional. A 6 mil or heavier PVC covering may be extruded over groups of conductors or the conductor assembly.
JacketPVC, major dia. in inches of 1.500 or less, 55 mils min average, 44 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnections or internal wiring of electronic equipment.