APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20875 Issued:1994-10-24
Revised:2019-11-07
Style 20875 Parallel Cable with Extruded Non-integral Jacket.

Rating80 deg C, 300 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's procedure.
AssemblyTwo parallel jacketed assemblies bonded together or extruded with a web to form a parallel cable. Individual jacketed assemblies shall each contain two or more insulated singles.
ShieldOptional.
JacketExtruded PVC
dia. in inches
0.700 or less30 mils min average24 mils minimum at any point
0.701-1.50 dia45 avg36 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024