Rating | 60 deg C, voltage not specified, Cable flame. |
|
Insulation | Labeled or complies with this Manufacturers AWM procedure. |
|
Assembly | Two or more insulated singles or groups of insulated singles cabled together to form a flat, oval or round assembly. Barrier layer and/or fillers optional. May use same or mixed AWG size. Manufacturer shall maintain a complete description of each assembly. |
|
Shield | Inner and outer shield are optional. |
|
Covering | Optional. 5 mil min. PVC covering may be extruded over the conductor assembly or PTFE, PFA, FEP, ETFE covering, 8 mils min average, 6 mils minimum at any point or foamed PE covering max 50 mils. |
|
Jacket | PVC |
| major dia. in inches |
| 0.700 or less | 60 mils min average | 48 mils minimum at any point |
| 0.701-1.000 dia | 80 avg | 64 min |
| 1.001-1.500 dia | 110 avg | 88 min |
| 1.501-2.500 dia | 140 avg | 112 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring and External Interconnection of Electronic Equipment. |
|