APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20879 Issued:1994-12-01
Revised:2019-11-07
Style 20879 Multiple-conductor cable using non-integral jacket

Rating60, 75, 80, 90, 105 deg C, 300 Vac, Cable flame.
Conductor36-10 AWG, solid or stranded round, tinned or bare copper.
InsulationLabeled or complying with the manufacturer's AWM Procedure.
AssemblyConsists of a max of six flat cables. Fillers or Tapes optional.
ShieldOptional. expanded metallic ground planes, one or both sides. The ground plane may be flat copper or aluminum and may be employed as a solid or mesh construction.
JacketExtruded PVC
Number o0f cablesdiameter in inchesmils minimum averagemils minimum at any point
three or less3.500 inches or less3024
four or more2.500 or less3024
four or more2.501-3.5004536
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024