APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20883 Issued:1995-03-10
Revised:2012-03-22
Style 20883 Parallel Cable with Extruded Insulation Using Extruded Non-Integral Jacket

Rating60, 80, 90, 105 deg C, 150, 300, 600 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyMultiple insulated singles laid parallel in one plane with optional shield and overall non-integral jacket.
ShieldOptional.
JacketExtruded PVC
Voltage ac¿Diameter of core assembly under jacket (inches)Minimum average thickness (mils)Minimum thickness at any point (mils)
3000.700 or less3024
3000.701-1.0004536
3001.001-1.5006048
3001.501-2.5008064
6000.700 or less4536
6000.701-1.0006048
6001.001-1.5008064
6001.501-2.5009576
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment.