Rating | 60, 80, 90, 105 deg C, 150, 300, 600 Vac, Cable flame. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Multiple insulated singles laid parallel in one plane with optional shield and overall non-integral jacket. |
|
Shield | Optional. |
|
Jacket | Extruded PVC |
| Voltage ac¿ | Diameter of core assembly under jacket (inches) | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 300 | 0.700 or less | 30 | 24 |
| 300 | 0.701-1.000 | 45 | 36 |
| 300 | 1.001-1.500 | 60 | 48 |
| 300 | 1.501-2.500 | 80 | 64 |
| 600 | 0.700 or less | 45 | 36 |
| 600 | 0.701-1.000 | 60 | 48 |
| 600 | 1.001-1.500 | 80 | 64 |
| 600 | 1.501-2.500 | 95 | 76 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of electronic equipment. |
|