APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20885 Issued:1995-03-17
Revised:2013-02-21
Style 20885 Multiple-conductor cable using non-integral jacket

Rating75 deg C, insulation 300 V (420 V peak), Jacket 600 V (840 V peak), Horizontal flame.
ConductorResistance Wire. Inner - 44-38 AWG, resistance alloy, solid nichrome wire. Outer - 14-18 AWG, braid copper over insulated conductor.
InsulationExtruded Foamed PE. 22 mils minimum thickness at any point, minimum average thickness not specified.
JacketExtruded PVC. 22 mils minimum average thickness, 18 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseProbe Cable for use with instruments where shield may carry a potential up to 600 V (840 V peak).