APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20895 Issued:1995-08-11
Revised:2019-11-07
Style 20895 Multiple conductor with extruded insulation.

Rating90 deg C, 1000 Vac, Cable flame.
Conductor40 AWG min - Material not specified.
InsulationLabeled or complies with manufacturer's AWM Procedure.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together. Lay not specified. Barrier layer over cable core or individual singles and/or fillers optional, manufacturer shall maintain a complete description of each assembly.
ShieldOptional. May be over one or more of the insulated conductors or applied over the assembly.
JacketPUR - See Facing Page for Compound
dia in inches
0.425 or less50 mils min average
426-0.700 dia66 avg
0.701-1.500 dia88 avg
1.501-2.500 dia120 avg
2.501 dia and larger154 avg
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseAs internal wiring or external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024