APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20899 Issued:1995-08-31
Revised:2012-03-06
Style 20899 Bonded or laminated flat ribbon cable

Rating80 deg C, 125 Vac, Horizontal Flame.
Insulated ConductorLabeled or complying with manufacturer's AWM procedure.
Assembly2-100 insulated singles or twisted pairs bonded between two sheets of PET film and polyester adhesive. Same or mixed conductor sizes.
CoveringPET film, 0.7 mils minimum average thickness bonded each side of insulated conductors, with polyester adhesive, 0.9 mils minimum average thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.