APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20904 Issued:1995-12-19
Revised:2019-11-07
Style 20904 Jacketed Cable.

Rating105 deg C, 600 Vac, Cable flame, Oil Resistant 60 deg C or 80 deg C (optional).
Conductor20 AWG - 2 AWG Stranded. Same as Type SE Cord.
InsulationTPE
20-15 AWG conductor size30 mils min average27 mils minimum at any point
14-10 AWG45 avg40 min
8-2 AWG60 avg54 min
AssemblyTwo to sixty individually insulated conductors or groups of insulated conductors to form a round cable. The length of lay of the twisted conductors or groups is not, shall be in accordance with Type SE Cord under the Standard for Flexible Cord and Fixture Wire, UL 62. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap.
JacketTPE
dia. in inhces
0.500 or less80 mils min average64 mils minimum at any point
0.501-0.750 dia95 avg76 min
0.7501-1.000 dia110 avg88 min
1.001-1.500 dia140 avg112 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of electronic equipment where the acceptability of the combination is to be accepted by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024