Rating | 60 deg C, 300 Vac, VW-1 flame. |
|
Conductor | 7 stranded 24 AWG or 19 stranded 22-16 AWG. |
|
Insulation | Labeled or complies with manufacturer's procedure with min rating of 60 deg C, 300 V and 12 mils min average. |
|
Assembly | Four or more singles and optional optical fiber members cabled around the strength member. Optical fiber core - Construction not specified. Strength Member - Stranded steel with minimum 12 mils of polyethylene or PVC covering. The length of lay of twisted singles is not specified. Fillers and/or barrier layer optional and their materials are not specified. Manufacturer shall maintain a complete description of each assembly. |
|
Shield | Optional. Copper braid only. |
|
Jacket | TPE. |
| Dia. of Cable Under Jacket | Min average | Min at any point |
| 0.275 inch or less | 40 mils | 32 mils |
| 0.276-0.425 inch | 50 mils | 40 mils |
| 0.425-0.700 inch | 60 mils | 48 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Remote Control on Interconnecting Cables for use with Professional Video and Audio Equipment in accordance with UL Standard 1419 where the acceptability is determined by UL LLC. |
|