Rating | 80 deg C, Voltage not specified, Cable flame. |
|
Conductor | 36 AWG minimum, Solid or stranded, tinned or bare. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure and minimum voltage rating of 300V. The designations of all styles of individual conductors used in making up the cable assembly shall be available. |
|
Barrier Layer | Optional barrier layer - may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap. |
|
Assembly | Two or more individually insulated conductors or groups of insulated conductors cabled together to form a round cable. A flat or oval cable may also be constructed with not more than three rows of single conductors or groups of conductors. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. Optional barrier layer. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors or over the shield, if provided. |
|
Shield | Optional. |
|
Covering | Optional. A 4 mil thick or thicker wall of thermoplastic covering may be extruded over the conductor assembly or groups of conductors (with or without shields). |
|
Jacket | PUR |
| major dia. in inches |
| 0.700 or less | 45 mils min average | 36 mils minimum at any point |
| 0.701-1.000 dia | 60 avg | 48 min |
| 1.001-1.50 dia | 80 avg | 64 min |
| 1.501-2.50 dia | 110 avg | 88 min |
| 2.500 dia and larger | 140 avg | 112 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection of electronic equipment. |
|