APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20912 Issued:1996-02-02
Revised:2012-04-23
Style 20912 Multiple-conductor cable using non-integral jacket

Rating60, 75, 80, 90, 105 deg C, 30, 90, 150, 300, 600 Vac, Cable Flame for Construction A, Horizontal Flame for Construction B.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo groups of conductors are laid parallel with an overall extruded PVC jacket which is joined together by an interconnecting web.
ShieldOptional.
CoveringOptional. A 10 mil thick or thicker, PVC covering may be extruded over the two groups that are laid parallel with an overall extruded PVC jacket which is joined together by an interconnecting web.
JacketExtruded PVC
Construction AConstruction B
Diameter of core assembly under jacket (inches)Min average thickness (mils)Min thickness at any point (mils)Min average thickness (mils)Min thickness at any point (mils)
0.350 or less30242016
0.351-0.70030243024
0.701-1.00040364036
1.001-1.50054485448
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseConstruction A: Internal wiring or external interconnection of electronic equipment. Construction B: Internal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024