APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20914 Issued:1996-03-27
Revised:2012-05-08
Style 20914 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 30 Vac, Cable flame.
InsulationLabeled or complies with this Manufacturer's AWM Procedure.
AssemblyTwo or more insulated singles or groups of insulated singles cabled together to form a flat, oval or round assembly. Barrier layer and/or fillers optional. May use same or mixed AWG size. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
CoveringOptional. 5 mil min PVC covering may be extruded over the conductor assembly or PTFE, PFA, FEP, ETFE covering, 8 mils minimum average, 6 mils minimum at any point.
ShieldOptional.
JacketExtruded PVC.
Diameter under cableMinimum average thicknessMinimum thickness at any point
0.350 inches or less20 mils17 mils
0.351-0.700 inches30 mils24 mils
0.701-1.000 inches45 mils36 mils
1.001-1.500 inches60 mils48 mils
1.501-2.500 inches80 mils64 mils
2.501-4.000 inches110 mils88 mils
4.001 inches or larger140 mils112 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring and External Interconnection in Class 2 Circuits of Electronic Equipment.