APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20916 Issued:1996-04-01
Revised:2019-11-07
Style 20916 Jacketed Cord.

Rating60 deg C, 150 Vac, Cable flame.
Conductor33 AWG - 18 AWG solid or stranded round, tinned or bare copper. May include mixed AWG sizes. (Lay not specified).
InsulationPE, 5 mils min average, 4 mils min at any point.
AssemblyTwo or more insulated conductors with optional shield, jacket and optional covering.
ShieldOptional.
CoveringOptional. Polyester 2 mils minimum at any point.
JacketPVC
dia. in inches
0.350 or less25 mils min average20 mils minimum at any point
0.351-0.700 dia30 avg24 min
0.701-1.000 dia40 avg36 min
1.001-1.500 dia54 avg48 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseHandset Wire or Telephone Cord for Subscriber Sets, or Internal or External Interconnecting Cable of Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024