APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20917 Issued:1996-04-11
Revised:2019-11-07
Style 20917 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 300 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
CoveringOptional. PVC covering may be extruded over the conductor assembly. Minimum thickness at any point, 6 mils.
ShieldOptional.
JacketExtruded PVC
major dia. in inches
0.700 or less30 mils min average24 mils minimum at any point
0.701-1.000 dia45 avg36 min
1.001-1.500 dia60 avg48 min
1.501-2.50 dia80 avg64 min
2.501-4.000 dia110 avg88 min
4.001 dia and larger140 avg112 min
ArmorOptional - Metallic braid of copper, stainless steel, aluminum or bronze.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment.