Rating | 200 deg C, 150 Vac, Horizontal flame, Construction A; Cable flame, Construction B. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. The designations of all styles of individual conductors used in making up the cable assembly shall be available. |
|
Assembly | Two or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A barrier layer, if employed, may be a fibrous wrap serving or braid; paper; nylon (polyamide); oriented polyethylene terephthalate; or thermoplastic-tape wrap. Such a barrier would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors. |
|
Shield | Optional. |
|
Jacket | Extruded FEP. |
| dia. in inches |
| 0.425 or less | (Const. A) | 10 mils minimum average thickness | 8 mils minimum thickness at any point |
| dia. in inches of 0.425 or less | (Const. B) | 20 mils minimum average thickness | 16 mils minimum thickness at any point |
| 0.426-0.700 dia | (Const. A) | 10 avg | 8 min |
| 0.426-0.700 dia | (Const. B) | 30 avg | 24 min |
| 0.701-1.500 dia | (Const. A) | 20 avg | 16 min |
| 0.701-1.500 dia | (Const. B) | 40 avg | 32 min |
| 1.501-2.500 dia | (Const. A) | 20 avg | 16 min |
| 1.501-2.500 dia | (Const. B) | 50 avg | 40 min |
| 2.501 dia and larger | (Const. A) | 30 avg | 24 min |
| 2.501 dia and larger | (Const. B) | 60 avg | 48 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Construction A: Internal wiring. Construction B: Internal or external wiring. |
|