Rating | 60 deg C, 30 Vac, Cable Flame. |
|
Conductor | 40-16 AWG, Solid or Stranded Round. Different conductor sizes may be used in one cord. |
|
Insulation | Labeled and complying with manufacturer's AWM procedure. See Facing Page for compound or Extruded TPES (Polyester Elastomer), wall thickness may vary from 3.5 mils minimim at any point to 30 mils. |
|
Assembly | Two to fifty conductors. Cable may be either straight or wound in retractile form. Core may be either flat (max 20 conductors) or round. Barrier layer and/or fillers optional. |
|
Shield | Optional. |
|
Jacket | Extruded PVC |
| major diameter in inches | mils minimum average | mils minimum at any point |
| 0.700 or less | 30 | 24 |
| 0.701-1.000 | 45 | 36 |
| 1.001-1.500 | 60 | 48 |
| 1.501-2.500 | 80 | 64 |
| 2.501-4.000 | 100 | 88 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring or External Interconnection of appliances. |
|