APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20927 Issued:1996-07-10
Revised:2012-05-30
Style 20927 Multiple-Conductor Cable using Non-Integral Extruded Jacket

Rating60 deg C, 30 Vac, Cable Flame.
Conductor40-16 AWG, Solid or Stranded Round. Different conductor sizes may be used in one cord.
InsulationLabeled and complying with manufacturer's AWM procedure. See Facing Page for compound or Extruded TPES (Polyester Elastomer), wall thickness may vary from 3.5 mils minimim at any point to 30 mils.
AssemblyTwo to fifty conductors. Cable may be either straight or wound in retractile form. Core may be either flat (max 20 conductors) or round. Barrier layer and/or fillers optional.
ShieldOptional.
JacketExtruded PVC
major diameter in inchesmils minimum averagemils minimum at any point
0.700 or less3024
0.701-1.0004536
1.001-1.5006048
1.501-2.5008064
2.501-4.00010088
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring or External Interconnection of appliances.