Rating | 60 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 30 AWG - 16 AWG solid or stranded round, tinned or bare copper. |
|
Insulation | PE or FRPE, 15 mils min average, 13 mils minimum at any point. |
|
Assembly | Three individually insulated wires cabled together. The length of lay of the twisted wires is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be 10 mils of extruded PVC, a fibrous wrap serving or braid, paper; nylon; oriented polyethylene terephthalate or a thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors or over the shield, if provided. |
|
Shield | Optional. |
|
Jacket | PVC, 15 mils min average, 12 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electronic equipment. Tabs may indicate the following: "600 Volts peak for Electronic Use Only." |
|