APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20936 Issued:1996-08-16
Revised:2012-10-04
Style 20936 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 300 Vac, Cable flame.
Insulated ConductorLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
CoveringOptional. A 6 mils or heavier PVC covering may be extruded over the conductor assembly.
ShieldOptional.
JacketExtruded TPU
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
2.501-4.000 inch110 mils88 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment (such as desk-type calculators, dictating machines, or x-ray equipment)

UL and the UL Logo are trademarks of UL LLC © 2024