Rating | 80 deg C, 30 Vac, Cable flame. |
|
Conductor | 40 AWG min, solid or stranded. |
|
Insulation | Labeled or complying with Manufacturer's AWM Procedure except that styles rated 30 Volts for Class 2 operation may not be used. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. May use same or mixed AWG size. |
|
Covering | Optional. Extruded PVC, 6 mil or heavier may be extruded over each twisted pair, groups of conductors, or the conductor assembly. |
|
Shield | Optional. |
|
Jacket | Extruded TPU. |
| Dia of cable under jacket in inches | Minimum average mils | Minimum at any point mils |
| 0.700 or less | 30 | 24 |
| 0.701-1.000 | 45 | 36 |
| 1.001-1.500 | 60 | 48 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of electronic equipment. |
|