APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20937 Issued:1996-08-16
Revised:2012-04-02
Style 20937 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 30 Vac, Cable flame.
Conductor40 AWG min, solid or stranded.
InsulationLabeled or complying with Manufacturer's AWM Procedure except that styles rated 30 Volts for Class 2 operation may not be used.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. May use same or mixed AWG size.
CoveringOptional. Extruded PVC, 6 mil or heavier may be extruded over each twisted pair, groups of conductors, or the conductor assembly.
ShieldOptional.
JacketExtruded TPU.
Dia of cable under jacket in inchesMinimum average milsMinimum at any point mils
0.700 or less3024
0.701-1.0004536
1.001-1.5006048
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024