| Rating | 80 deg C, 600, 1000 Vac, Horizontal flame. |
|
| Conductor | 32 AWG minimum. solid or stranded round. |
|
| Insulation | Labeled or complying with Manufacturer's AWM Procedure. |
|
| Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductor is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
| Shield | Optional. |
|
| Covering | Optional. A 6 mil or heavier covering may be extruded over the conductor assembly. |
|
| Jacket | Extruded TPU. |
| Diameter of cable under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.350 inch or less | 30 mils | 24 mils |
| 0.351-0.700 inch | 45 mils | 36 mils |
| 0.701-1.000 inch | 60 mils | 48 mils |
| 1.001-1.500 inch | 80 mils | 64 mils |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring of electronic equipment and appliances. |
|