APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20943 Issued:1996-10-25
Revised:2012-03-22
Style 20943 Parallel Cable with Extruded Integral Insulation and Jacket

Rating105 deg C, 600 Vac, Horizontal flame.
Conductor40 AWG - 12 AWG Flat, 0.8 - 10.0 mils thick, 10-100 mils wide.
InsulationPET, 2 mils minimum average thickness, integral with Jacket.
AssemblyTwo to 150 conductors laid parallel in one plane. On each side of the conductors, irradiated 0.5 mils minimum thickness of flame retardant polyolefin (FRPO) adhesive bonded to 1.6 mils minimum thickness of biaxially oriented PET (PETP) film. Minimum 20 mils insulation width on outside edges of conductors and 20 mils minimum insulation width between adjacent conductors. Length of insulated conductors not specified.
ShieldOptional.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024