Rating | 80 deg C, 30 Vac, 120 Vac, 600 Vac, Cable flame. |
|
Conductor | 40 AWG min. Solid or stranded. |
|
Insulation | Labeled or complying with Manufacturer's AWM Procedure. The voltage rating of any of the single insulated conductors in a group shall not be less than the voltage rating printed on the surface of the PVC jacket covering that group. |
|
Assembly | Three groups of individually insulated conductors cabled together to forming a Flat Cable. The length of lay of the twisted conductors is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic tape wrap. The barrier may be applied over the twisted assembly of individual conductors, groups of conductors or individual conductors. Uninsulated conductors may be cabled in with insulated conductors for grounding. |
|
Shield | Optional. |
|
Jacket | Extruded TPU |
| dia. in inches |
| 0.425 or less | 45 mils min average | 36 mils minimum at any point |
| 0.426-0.700 dia | 60 avg | 48 min |
| 0.701-1.50 dia | 80 avg | 64 min |
| 1.501-2.500 dia | 110 avg | 88 min |
| 2.501 dia and larger | 140 avg | 112 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring and External Interconnection of Electronic Equipment. |
|