Rating | 80 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 32 AWG minimum, solid or stranded. |
|
Insulated Conductor | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductor is not specified. A barrier layer and/or fillers are optional. May use same or mixed AWG size. |
|
Covering | Optional. |
|
Shield | Optional. |
|
Jacket | Extruded PVC. |
| Diameter of cable under jacket* | Minimum average thickness | Minimum thickness at any point |
| 0.350 inch or less | 15 mils | 12 mils |
| 0.351 - 0.700 inch | 30 mils | 24 mils |
| 0.701-1.000 inch | 45 mils | 36 mils |
| 1.001-1.500 inch | 60 mils | 48 mils |
| *Major diameter if cable is flat or oval. |
|
Braid | Optional. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electronic equipment and appliances. Tags may indicate the following: "600 volts Peak for Electronic use only". |
|