APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20954 Issued:1997-03-12
Revised:2012-03-22
Style 20954 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 300 Vac, Cable flame.
Conductor33-18 AWG, solid or stranded or tinsel. May include mixed AWG sizes.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more conductors may be either straight or wound in retractile form. Core may be either flat or round. Barrier layer and/or fillers optional.
ShieldOptional.
JacketExtruded TPU, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment, or as "Handset Wire Or Telephone Cord For Subscriber Sets", where the final acceptability is to be determined by Underwriters Laboratories.