APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2096 Issued:1959-05-01
Revised:2013-01-03
Style 2096 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG, solid or stranded.
InsulationExtruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
AssemblyTwo to eight conductors.
ShieldOptional.
JacketExtruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Appliances and Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024