APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20961 Issued:1997-05-01
Revised:2013-02-21
Style 20961 Bonded or laminated flat ribbon cable

Rating105 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG minimum. Solid or stranded.
InsulationLaminated or extruded PVC. 5 mils minimum average thickness, 3 mils minimum thickness at any point. Conductors may be coated with Polyimide.
AssemblyTwo to 150 conductors, 3 mils minimum between conductors and 3 mils minimum edge width. Conductors may be coated with Polyimide.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Class 2 Circuits in Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024