Rating | 80 deg C, 30 Vac, Use No.l Horizontal Flame, Use No. 2 Cable Flame. |
|
Conductor | 50 AWG minimum, solid or stranded. |
|
Insulation | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Two or more twisted singles or groups of twisted singles twisted together or two or more conductors or groups may be laid parallel to form flat, oval, or round cables. May use same or mixed AWG. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. |
|
Covering | Optional, Extruded PVC, 13 mil minimum at any point or extruded TPE, 6 mil minimum at any point. |
|
Shield | Optional. |
|
Jacket | Extruded TPU |
| Dia. of cable under jacket in inches | Minimum average (mils) | Minimum at any point (mils) |
| 0.300 or less | 15 | 12 |
| 0.301-0.450 | 22 | 17 min |
| 0.451-0.550 | 30 | 24 |
| 0.551-0.800 | 60 | 48 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Use No. 1 Internal wiring in Class 2 circuits of electronic equipment where each end is terminated in connectors.
Use No. 2 Internal wiring in Class 2 circuits of electronic equipment or external interconnection in Class 2 circuits of electronic equipment where not routed along walls, floors, or other abuse areas. |
|