APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20963 Issued:1997-04-24
Revised:2014-05-30
Style 20963 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 30 Vac, Use No.l Horizontal Flame, Use No. 2 Cable Flame.
Conductor50 AWG minimum, solid or stranded.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together or two or more conductors or groups may be laid parallel to form flat, oval, or round cables. May use same or mixed AWG. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
CoveringOptional, Extruded PVC, 13 mil minimum at any point or extruded TPE, 6 mil minimum at any point.
ShieldOptional.
JacketExtruded TPU
Dia. of cable under jacket in inchesMinimum average (mils)Minimum at any point (mils)
0.300 or less1512
0.301-0.4502217 min
0.451-0.5503024
0.551-0.8006048
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseUse No. 1 Internal wiring in Class 2 circuits of electronic equipment where each end is terminated in connectors. Use No. 2 Internal wiring in Class 2 circuits of electronic equipment or external interconnection in Class 2 circuits of electronic equipment where not routed along walls, floors, or other abuse areas.