Rating | 250 deg C, 600 Vac, Horizontal flame. |
|
Conductor | 18 AWG - 12 AWG stranded. Conductive Core - Over the conductor is an extruded semi-conductor high temperature thermoplastic. |
|
Insulation | MFA or PFA, see Facing Page for Compound, 20 mils min average, 18 mils minimum at any point. |
|
Assembly | Two or three conductors with conductive core, optional inner covering, optional shield, optional outer covering. |
|
Shield | Optional. |
|
Covering | Inner - (Optional) 12 mils min at any point, extruded perfluoralkoxy (PFA) or MFA (Chlorosulfonated polyethylene, see facing page for compound). Outer - (Optional)13 mil min at any point, extruded perfluoralkoxy (PFA) or MFA (Chlorosulfonated polyethylene, see facing page for compound) |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Pipe-heating cable where the acceptability of the combination is to be determined by Underwriters Laboratories Inc. |
|