APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2098 Issued:1959-05-01
Revised:2012-03-15
Style 2098 Multiple conductor cable using non-integral jacket.

Rating90 deg C, 300 Vac, Horizontal flame.
Conductor26 AWG - 16 AWG.
InsulationExtruded PVC, 15 mils minimum average thickness, 14 mils minimum thickness at any point.
AssemblyTwo conductors.
ShieldOne or both conductors may have shielding consisting of Nos. 38-30 AWG tinned copper strands applied as a wrap or braid.
JacketExtruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor Electronic Use in Non-Hazardous Locations.

UL and the UL Logo are trademarks of UL LLC © 2024