APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20980 Issued:1998-02-11
Revised:2012-01-10
Style 20980 Flat Ribbon Cable

Rating105 deg C, 600 Vac, Horizontal flame.
Conductor36 AWG - 16 AWG solid or stranded, and conductors from 3000 CMA to 25000 CMA.
InsulationExtruded PVC, 50 mils min average thickness, 45 mils minimum thickness at any point.
AssemblyOne to six conductors and two uninsulated braided conductors laid parallel with an overall PVC insulation.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Appliances.