APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20983 Issued:1998-02-16
Revised:2019-11-07
Style 20983 Multiple-conductor cable using non-integral jacket.

Rating90 deg C, 1000 Vac, Cable flame.
Conductor30 AWG - 2/0 AWG solid or stranded.
InsulationExtruded XLPE
30-11 AWG conductor size15 mils minimum average thickness13 mils minimum thickness at any point
10-2 AWG20 avg18 min
AssemblyConsists of three or four circuit conductors with three or four grounding conductors twisted together forming round cable. The lay of the conductors is not specified.
ShieldOptional.
CoveringExtruded 30 mil minimum thickness PVC covering shall beextruded over the conductor assembly.
JacketExtruded PVC
dia. in inches
0.425 or less45 mils minimum average thickness36 mils minimum thickness at any point
0.426-0.700 dia60 avg48 min
0.701-1.600 dia80 avg64 min
1.601-2.500 dia110 avg88 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal wiring.