APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20984 Issued:1998-03-10
Revised:2011-10-18
Style 20984 Laminated flat ribbon cable.

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor40 AWG - 12 AWG Flat, maternal no specified, 0.8-1.0 mils thick, 10-100 mils wide.
InsulationPI film, 0.8 mil minimum thickness, with thermosetting adhesive, 0.5 mil minimum thickness, bonded each side of conductors, 10 mils minimum edge width and 10 mils minimum distance between conductors.
AssemblyTwo to 150 conductors straight or irregular parallel in one plane. Length of insulated conductors not specified.
ShieldOptional.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024