APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20990 Issued:1998-03-25
Revised:2012-04-19
Style 20990 Multiple-conductor cable using non-integral jacket.

Rating200 deg C, 600 Vac, Horizontal flame.
Conductor18 AWG - 12 AWG, stranded.
InsulationExtruded FEP, 20 mils minimum average thickness, 18 mils minimum thickness at any point.
Conductive CoreOver the conductor is an extruded semi-conductive high temperature thermoplastic.
AssemblyTwo to three conductive cores with insulation, optional shield and jacket.
ShieldOptional.
JacketExtruded FEP, 13 mils minimum average thickness, 10 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePipe-heating cable where the acceptability of the combination is to be determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024