APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20992 Issued:1998-05-21
Revised:2012-01-12
Style 20992 Laminated Flat Cable.

Rating105 deg C, 600 Vac, Horizontal flame.
Conductor30 AWG - 16 AWG solid or stranded round, tinned or bare copper.
InsulationLabeled or complying with manufacturer's AWM procedure, 10 mils min average, 9 mils minimum at any point.
AssemblyTwo to twenty insulated singles, laid parallel in one plane, with a PVC covering forming a flat ribbon-type cable. May include mixed AWG sizes. Manufacturer shall maintain a record of all singles used in each cable. Sections may be split into singles or groups of conductors.
CoveringExtruded PVC, 4 mils min at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024