APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20995 Issued:1998-05-11
Revised:2019-11-07
Style 20995 Multiple-conductor cable using non-integral jacket

Rating90 deg C, 300 Vac, Cable flame.
Conductor36 AWG - 10 AWG solid or stranded round, tinned or bare copper.
InsulationLabeled or complying with manufacturer's AWM procedure
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional. A 6 mil or heavier PVC covering may be extruded over two or more conductors or the conductor assembly.
JacketPUR
dia. in inches
0.700 or less35 mils min average28 mils minimum at any point
0.701-1.000 dia45 avg36 min
SEE FACING PAGE FOR COMPOUND
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024