APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20997 Issued:1998-05-20
Revised:2011-12-29
Style 20997 Multiple Conductor Cable Using Non-integral Jacket.

Rating105 deg C, 600 Vac, Cable flame, Oil Resis. 60 degC, Moisture Resis. 60 degC, 720hr Sunlight Resis.
Conductor26 AWG - 16 AWG solid or stranded round.
InsulationConsists of four labeled insulated conductors, Style 1230, and one labeled PTFE insulated coaxial cable with 38 gauge single-end, silver-plated copper braid and extruded FEP covering, Style 1354
AssemblyConsists of four insulated conductors cabled with one coaxial cable. The length of lay of the conductors is not specified.
Fillers(Optional)Extruded Polypropylene Rod with 85 mils maximum average outside diameter.
ShieldAluminum Foil with 50% overlap covered with tinned or bare Copper Braid consisting of No. 35 AWG or smaller strands. 85 percent coverage minimum.
JacketTPE, 80 mils min average, 64 mils minimum at any point. 720 hour sunlight resistant. TPE shall not be of the styrenic type.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial Use Outdoor power supply cord; 105 deg C dry, 60 deg C wet, 60 deg C oil where the acceptability of the combination is to be determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2025