Rating | 80 deg C, 30 Vac, Horizontal flame. |
|
Conductor | 50 AWG minimum, material not specified. |
|
Insulation | PFA, 3 mils min at any point. |
|
Assembly | Two to more insulated conductors with optional drain wire, optional shield and jacket sprially wrapped, two or more layers of PET. Each layer applied with 25 percent minimum overlap and heat sealed. |
|
Shield | Optional. Drain Wire - Optional. |
|
Jacket | POLYESTER TAPE, 0.2 mils min at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring of Electronic Equipment in Class 2 Circuits. |
|