APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21001 Issued:1998-09-08
Revised:2015-09-28
Style 21001 Multiple-conductor cable using non-integral jacket

Rating60 or 80 deg C, Voltage Not Specified, Cable Flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
JacketExtruded THV or ETFE or FEP or PFA or PTFE, TFE
*Diameter of cable under jacket in inchesmils minimum averagemils minimum at any point
0.500 or less1814
0.501-0.7002520
0.701-1.0003528
1.001-1.5004536
1.501-2.5006048
2.501-4.0008064
4.001 dia and larger11088
*Major diameter if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring or Internal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024