APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21003 Issued:1998-08-18
Revised:2012-07-19
Style 21003 Multiple Conductor Cable with Extruded Insulation with a Non-extruded Non-integral Jacket.

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor50 AWG minimum.
InsulationExtruded FEP, 2 mils min at any point.
AssemblyConsists of two or more insulated conductors with optional drain wire, optional shield and jacket sprially wrapped PET.
ShieldOptional.
JacketSprially wrapped, two or more layers of PET. Each layer applied with 25 percent minimum overlap and heat sealed. Overall minimum thickness 0.2 mil at any point.
Misc.Drain Wire - Optional.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Electronic Equipment in Class 2 Circuits.