APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21007 Issued:1998-10-09
Revised:2012-03-22
Style 21007 Multiple-Conductor Cable Using Non-Integral Jacket

Rating60 deg C, 30 Vac, Cable flame.
Conductor36 AWG - 16 AWG solid or stranded, mixed size.
InsulationLabeled or complies with manufacturer's AWM Procedure. Extruded PP, 6 mils minimum average thickness, 3.5 mils minimum thickness at any point.
AssemblyTwo to fifty insulated conductors laid straight or wound in retractile form. Core may be either flat (maximum 20 conductors) or round. Barrier layer and/or fillers optional.
ShieldOptional.
JacketExtruded TPU
Diameter of core assembly under jacket (inches) ¿Minimum average thickness (mils)Minimum thickness at any point (mils)
0.425 or less2318
0.426-0.7004536
0.701-1.5006048
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of appliances or electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024