| Rating | 60 deg C, 30 Vac, Horizontal flame (internal use), cable flame (external use). |
|
| Conductor | 30 AWG min. solid or stranded. |
|
| Insulation | Extruded PE, 7 mils min average thickness. |
|
| Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. |
|
| Shield | Optional. |
|
| Jacket | Extruded PVC |
| major dia. in inches |
| 0.250 or less | internal use | 19 mils min average | 15 mils minimum at any point |
| major dia. in inches of 0.250 or less | external use | 17 mils min average | 14 mils min at any point |
| 0.251-0.425 dia | internal and external use | 30 avg | 24 min |
| 0.426-0.700 | internal and external use | 45 avg | 36 min |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Construction AInternal wiring of electronic equipment.Construction BExternal interconnection of electronic equipment. |
|