APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21019 Issued:1999-02-01
Revised:2012-04-02
Style 21019 Multiple-conductor cable using non-integral jacket.

Rating150 deg C, 250 Vac, Horizontal flame.
Conductor36 AWG - 20 AWG, solid or stranded.
InsulationExtruded PTFE, 6 mils minimum average thickness, 5 mils minimum thickness at any point.
AssemblyTwo or more insulated singles optionally twisted around teflon filler or breather tube and with optional inner jacket, optional shield and outer jacket. Fillers may be used to form round cable.
Inner JacketOptional. Extruded SR, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
ShieldOptional.
JacketExtruded SR.
Dia of cable under jacketMin. Avg. Thickness milsMin. thickness at any point mils
0.200 or less3024
0.201-0.3004536
0.301-0.4006048
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024